Single Wall Stove Pipe Clearance
The minimum installation clearances for certified double wall flue pipes are much less than those for single wall pipes.
Single wall stove pipe clearance. Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall. Use our 24 ga. Thd sku 699214. Duravent single wall stove chimney pipe vents exhaust from your stove.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls. Single wall black stove pipe to connect wood burning appliances to chimneys. Clearance from combustible components. Compatible with most wood stoves.
Simply put our single wall black pipe is a superior product to dura vent snap lock and all other makers of black stove pipe. Choose your stove pipe type. Rock vent single wall stove pipe is cold rolled 22 gauge mild steel rust free and is perfectly round for a precise pipe to pipe fit the perfect fit is a result of the use of the latest techniques in laser butt welding and forming technology. 6 single wall or double wall stove pipe.
Many think stovepipe can run from the wood stove right up through the ceiling and roof. We also offer close clearance connector pipe that requires only 6 inch clearance to combustibles. Metal flue fire clearance codes. Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove. Stove pipe is used from the top of the woodstove or freestanding fireplace to the bottom of the ceiling or wall where it will connect to class a chimney pipe or a masonry chimney. Single wall stove pipe radiates more heat into the room than double wall stove pipe and requires 18 clearance from combustible surfaces where. Combustible clearance specifications for single wall metal flues.
24 gauge frame provides long lasting use. This one is the sealed type. Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling. Fire safety clearance required from combustibles for single wall metal flue vent connectors what are the required distances between flue vent.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe. This article describes the fire safety clearance distances required between oil and gas fired heating equipment and the nearest combustible surfaces. Single wall stove pipe is not intended for use as a chimney it is a connector pipe only.